[email protected] +86-21-58386189, 58386176

Jet Sparger – Internal View

Sparger is designed for water and slurry heating for both tank and inline applications. The unique design of internal steam control allows the PSX Jet Sparger to deliver high velocity steam to promote rapid condensation and mixing of the steam. An internal stem plug opens and closes to inject steam through the engineered diffuser. Features ...

Air Sparging Design Paradigm - CLU-IN

air sparging design paradigm This document is a product of the air sparging research and development efforts sponsored by the U.S. Air Force Research Laboratory, Airbase and Environmental Technology Division, Tyndall Air Force Base

Teesing - Optimal mass transfer of oxygen or carbon ...

Or the sparger tip can be cleaned out-of-place using a number of methods, including ultrasound or a detergent and water flush. Either way, the Quick Change Sparger can help make sparger change out simple and easy. Changing to new clean sparger tips after each batch is an excellent method of maintaining GMP process validation methods.

Steam sparger design - Chemical process engineering - Eng-Tips

Steam sparger design Steam sparger design Law (Mechanical) (OP) 21 Feb 16 13:26. So I have a situation here. I have a tank that has steam injection into it via a south sparger 4" inlet 125# steam. The north sparger is 3" 125# steam. I need to get 12500 # per hour through these spargers. I designed two 3" spargers with spray tips on them.

Design of ring and spider type spargers for bubble column ...

The sparger design is critical over the entire range of superficial gas velocity in bubble columns having low H/D ratio (Haque et al., 1986).In particular, in the range of 1 < H L /D < 5, the internal liquid circulation is under development and hence sparger design governs the flow pattern and hence the performance of the bubble column. The various spargers commercially available can be ...

Sparger Design Guide | Gases | Porosity | Free 30-day ...

INTRUSIVE PIPELINE SPARGER DESIGN GUIDE Gas Exit Velocity Chart Intrusive Pipe Line Sparger Sizing If Then Intrusive pipe line sparger sizing, where the sparg- 1 - 5 FPS** 25 FPM design er element is located inside of the pipe line, is 50 FPM maximum based on the superficial Gas Exit Velocity from the sparger element in relation to the liquid ...

Heating Liquids by Steam Sparging - Accendo Reliability

Steam is often used for heating liquids. Heat is provided to a liquid either through a heat exchanger or by direct injection of raw steam. The injection of steam directly into the process is known as steam sparging. The sparge design and location affect the efficiency of the process.

Resource Center - Mott Corp

Resource Center. Check out the information about our products and applications. If you don't find what you're looking for, do a quick search or feel free to email us directly. You may need to disable pop-up blocker to view certain PDF files.

Also appeared in CHEMICAL ENGINEERING PROGRESS

design of these units enables them to efficiently and quickly provide hot water, as well as offer an initial cost advantage. Yet, neither the tank sparger nor the mixing tee affords the user the full advantage that other, more-sophisticated direct-contact steam injection …

Review Bubble column reactors - ULisboa

Review Bubble column reactors Nigar Kantarcia, Fahir Borakb, Kutlu O. Ulgena,* aDepartment of Chemical Engineering, Bog˘azic¸i University, 34342 Bebek-Istanbul, Turkey bDepartment of Chemical Engineering, Yeditepe University, 34755 Kadikoy-Istanbul, Turkey Received 31 August 2004; accepted 26 October 2004 Abstract Bubble columns are intensively used as multiphase contactors and reactors …

DESIGN OF VENT GAS COLLECTION AND DESTRUCTION SYSTEMS

Mar 10, 2015· DESIGN OF VENT GAS COLLECTION AND DESTRUCTION SYSTEMS 1. Refinery Process Stream Purification Refinery Process Catalysts Troubleshooting Refinery Process Catalyst Start-Up / Shutdown Activation Reduction In-situ Ex-situ Sulfiding Specializing in Refinery Process Catalyst Performance Evaluation Heat & Mass Balance Analysis Catalyst Remaining Life Determination …

Steam Sparger | High Velocity Steam Heating - ProSonix

Pipe mount design for inline heating; Design for Mass Flow or Trim Temperature Heating; Can be used on oversized pipes (>12.0" dia.) for high flowrate fluid heating & winter freeze protection; VIEW/DOWNLOAD PDF Contact jet sparger direct steam injection heater manufacturers for a free quote on the top of the line PSX Jet Sparger Steam ...

Design Guide & Part Selection

INLINE DYNAMIC SPARGER DESIGN GUIDE Non-Intrusive Inline Dynamic Sparger Sizing Sizing is based on liquid flow. Nominal flow rate is based on 10 FPS linear velocity through the ID of the Dynamic Sparger. These spargers can operate effectively from less than 5 FPS up to 20 FPS. Select the Dynamic Sparger Model 8501 or

Cyclone design - Step by step guide - Powderprocess.net

4. Cyclones step by step design guide How to design cyclones ? This design guide is based on the works published by Bohnet in 1997. The approach is valid for standard cyclones with squared tangential inlets and with a small dust load in the order of max 10 g/m3.

simplified sparger design - casaldigioia.it

INLINE DYNAMIC SPARGER DESIGN GUIDE NonIntrusive Inline Dynamic Sparger Sizing Sizing is based on liquid flow. Nominal flow rate is based on 10 FPS linear velocity through the ID of the Dynamic Sparger. These spargers can operate effectively from less than 5 FPS up to 20 FPS.

Thermo Scientific HyPerforma Single-Use Bioreactor …

Sparger Designs Open Pipe Sparger The open pipe sparger design (figure 2.3) is based on a simple open pipe formed from a molded silicone port adapter which extends 3.8cm (1.5") into the standard S.U.B. BPC. The inner diameter (ID) of the open pipe sparger varies across the S.U.B. product line as indicated in table 2.1.

Sparger Design Guide | Gases | Porosity | Avaliação ...

INTRUSIVE PIPELINE SPARGER DESIGN GUIDE Gas Exit Velocity Chart Intrusive Pipe Line Sparger Sizing If Then Intrusive pipe line sparger sizing, where the sparg- 1 - 5 FPS** 25 FPM design er element is located inside of the pipe line, is 50 FPM maximum based on the superficial Gas Exit Velocity from the sparger element in relation to the liquid ...

bbi-biotech Shop | Category Ring-Sparger

bbi-biotech Shop | Category Ring-Sparger. The ring sparger is a sparger pipe with ring sparger for installation in the lid of the culture vessel. The ring has small holes that, when connected to pressure air, distribute air as fine bubbles in the bioreactor / fermentor to allow effective aeration.

OPTIMIZATION OF AIR-INJECTION SPARGERS FOR …

effects of various design and operating variables on the performance of a commercial gas sparging system. The data collected from this work was used to develop operational guidelines that plant operators can employ to improve column performance and to correct flaws in the design …

Tank Agitation Regenair Blowers

Sparger pipe size 3⁄ 4"1" 11⁄4"11⁄2"2" 21⁄2"3" 4" Check existing sparger pipe size to see if it fits the range. If not, the sparger size will need to change to achieve good air distribution. Sparger Holes 7. Determine minimum/maximum number of holes per sparger pipe. Holes should be no closer than 2" or farther than 5" apart. Holes are ...

Sparger: design - Chemical plant design & operations - Eng ...

Dec 24, 2008· RE: Sparger: design rmw (Mechanical) 24 Dec 08 18:22 I'd like to know more about your condensate conditions, temperature and from whence it came (meaning did it come from a source where some of it flashed as it came across a trap or the like or is all the flashing strictly due to pressure drop along the condensate piping?)

Heating Liquids by Steam Sparging - Accendo Reliability

Steam Sparger Calculation - posted in Student: Good day to you all. I am cunrrently doing my plant design of a refinary plant. I am facing problem of designing the steam sparger for my bleaching part vessel. Based on MOTT corporation infomation given, My steam mass flow that caluclated is only 0.87kg/hr. is it possible? My vessel is around 2 * 4 meter square, operating at 110C and o.1bar.

Effect of gas sparger design on bubble column ...

Needle sparger ("fine gas spargers", Fig. 2b). The needle sparger was designed to produce smaller bubbles (because of the small sparger opening and the mechanics of the bubble growth and detachment) and generate stable and mono-dispersed flow, as qualitatively displayed in Fig. 3.The sparger consists of a sparger zone and a plenum.