15+ Different Types of Cement - Their Definition ...

A number of different types of cement are manufactured, by varying the ratio of the raw material and/or by adding some additional materials. Some of the most common cement classifications are: 1. Ordinary Portland Cement. 2. Rapid hardening cement, 3. Ultra-rapid hardening cement.

BET theory - Wikipedia

Brunauer–Emmett–Teller (BET) theory aims to explain the physical adsorption of gas molecules on a solid surface and serves as the basis for an important analysis technique for the measurement of the specific surface area of materials. In 1938, Stephen Brunauer, Paul Hugh Emmett, and Edward Teller published the first article about the BET theory in the Journal of the American Chemical Society.

Figuring the Specific Surface Area| Concrete Construction ...

Figuring the Specific Surface Area Concrete Production & Precast. Posted on: December 01, 2002. Figuring the Specific Surface Area. I am looking for a way to calculate the specific surface area (total surface area) of an aggregate that I am using in concrete. This ...

Specific surface area - How is Specific surface area ...

Looking for abbreviations of SSA? It is Specific surface area. Specific surface area listed as SSA. Specific surface area - How is Specific surface area abbreviated? ... Huber Carbonates diagrams where the HuberCrete products fall within the median particle size and specific surface area range versus other concrete mixture ... Specific surface ...

Strength of Concrete

Both, surface and the cement-gel reacts at the sub-microscopic level; hence the theory that smooth surfaced particles yield poor concrete is not fully justified. Angular aggregates have higher specific surface area than smooth rounded aggregate. With a greater specific surface area the angular aggregate may show higher bond strength than ...

Blaine Air Permeability Apparatus

The Blaine Air Permeability Apparatus determines the fineness of Portland cement in terms of specific surface area expressed as the total surface area in square centimeters per gram of mortar or cement. The Blaine works by drawing a definite quantity of air through of bed of cement exhibiting a …

Silica fume - Wikipedia

Silica fume is an ultrafine material with spherical particles less than 1 μm in diameter, the average being about 0.15 μm. This makes it approximately 100 times smaller than the average cement particle. The bulk density of silica fume depends on the degree of densification in the silo and varies from 130 (undensified) to 600 kg/m 3.The specific gravity of silica fume is generally in the ...

ITZ microstructure of concrete containing GGBS - ScienceDirect

Fig. 5 is an XRD diagram of paste containing GGBS (specific surface area 600 m 2 /kg) partially replacing Portland cement at a weight fraction of 40%. It is indicated in Fig. 5 that the CH peak height at 7 days is not as high as that in Fig. 4; this means that the pozzolanic reaction of GGBS in the sample starts to consume CH at 7 days.It means that the pozzolanic reaction of GGBS (specific ...

BET (Brunauer, Emmett and Teller) | Particle Analytical

The BET instrument applied by Particle Analytical (Micromeritics Gemini 2375 and Gemini V) determines the specific surface area (m²/g) of pharmaceutical samples. The samples are dried with nitrogen purging or in a vacuum applying elevated temperatures. Unless otherwise instructed we use P/P0 of 0,1, 0,2 and 0,3 as standard measurement points.

BET Specific Surface Area - Particle Technology Labs

The BET (Brunauer, Emmett and Teller) theory is commonly used to evaluate the gas adsorption data and generate a specific surface area result expressed in units of area per mass of sample (m 2 /g). The technique is referenced by several standard organizations such as ISO, USP and ASTM.

Specific surface area - Wikipedia

Specific surface area (SSA) is a property of solids defined as the total surface area of a material per unit of mass, (with units of m 2 /kg or m 2 /g) or solid or bulk volume (units of m 2 /m 3 or m −1).. It is a physical value that can be used to determine the type and properties of a material (e.g. soil or snow).It has a particular importance for adsorption, heterogeneous catalysis, and ...

What is rapid hardening cement? - Quora

Aug 29, 2018· Rapid Hardening Cement (RHC) are also called high early strength cement. The prime difference between the rapid hardening cement and ordinary Portland cement is the lime content. Large proportion of lime is the distinguishing feature of rapid hard...

Effect of Fineness of Cement on Concrete Properties ...

Fineness of cement is a characteristic property of cement that signifies the particle size of cement and its specific surface area. Greater fineness of cement means the particles are finer and had more surface area. In case of very coarse cement, under some conditions it can cause a serious bleeding problem on some construction projects.

11/22/2016 30(4) Harmonization: <846> SPECIFIC …

surface area less than about 0.5 m 2 g 1) krypton is the preferred adsorbate gas, while for samples of greater surface area, nitrogen is preferred. A minimum of three mixtures of the appropriate adsorbate gas with helium are required within the P / P o range 0.05 to 0.30, such as 0.100, 0.200,

2. How can the characteristics of nanomaterials be ...

The specific surface area as determined by the BET method (Brunauer et al. 1938) has the advantage of being independent of the primary versus the agglomerated state. Scientific toxicological data suggest that the total surface area of nanoparticles is a reasonable metric to describe toxicological responses in biological systems.

Constituent Materials of Concrete - InterNACHI®

The total surface area of the particles in a given volume of material is called its specific surface. Portland cements have a specific surface of 1,500 to 2,000 square feet per pound of material (ft 2 /lb), equal to around 300 to 400 square meters per kilogram (m 2 /kg), depending on type.

12. TESTING OF CEMENT – PART 1. - cvut.cz

Chapter 12-Testing of Cement – Part 1 page 61 A bed of cement is prepared in special permeability cell and have exact porosity e = 0,500 weight a quantity of cement. The weight of the cement is calculated from where ρ is the density of the cement [g.cm-3] V volume of the cement bed [cm 3] Specific surface S is expressed as

Measurement of particle size distribution and specific ...

1. Introduction. The concrete aggregate industry has historically limited particle size distribution (PSD) analysis, for fine particles, to simply determining the mass fraction of particles passing a sieve with square openings of minimum edge length 0.063 mm (according to EN 933-1 ) or 0.075 mm (according to ASTM C136).The European industry standard method intended for analysing the grading of ...

FINENESS OF CEMENT BY BLAINES AIR PERMEABILITY METHOD …

Jun 18, 2014· S 0 =Specific surface of reference cement. ρ 0 =Density of reference cement. t 0 =Mean of three measured times. η 0 =Air viscosity at the mean of the three temperatures. (d)Determination of fineness. Repeat the steps (1 to 6) as done in determination of apparatus constant, but this time using the cement whose fineness is to be calculated.

Specific surface area of cement - YouTube

Mar 06, 2018· Cement consistency test procedure by vicat apparatus, quality control test for cement, london cement - Duration: 16:22. Constructiontest org 95,885 views

The Surface Area of Hardened Cement Paste as Measured by ...

surface area of the C-S-H gel is quite variable, with a conservative value being 200 m2/g. To put this in perspective, the specific surface area of (unhydrated) portland cement powder is less than 1 m2/g, while the surface area of a fine silica fume with an average particle size of 100 nm has a surface area of around 20 m2/g [5].

2.3: BET Surface Area Analysis of ... - Chemistry LibreTexts

Jan 10, 2020· Once X m is determined, the total surface area S t can be calculated with the following equation, where L av is Avogadro's number, A m is the cross sectional area of the adsorbate and equals 0.162 nm 2 for an absorbed nitrogen molecule, and M v is the molar volume and equals 22414 mL, ref{4} .

Ordinary Portland Cement / ASO CEMENT

Ordinary Portland Cement is suitable for general purpose buildings, shot concrete, civil engineering works, etc. Testing result (example) Item: Ordinary Portland Cement: JIS * Standards (JIS R 5210) Density (g/cm 3) 3.15-Specific Surface Area (cm 2 /g) 3310: More than 2500: Setting: Initial Set h-min Final Setting h-min: 2-10 3-15: More than ...